Measure impedance between terminals of
primary coil.
Standard value:0.4Ω±10%(20℃)
Impedance value within the range is good.
Impedance value “∞” indicates broken wire
inside the coil. The coil shall be replaced.
2.5.3 Secondary coil
Provided with a spark plug. Measure impedance between lead-wire side of spark plug cap and
terminal.
Standard value:8-11KΩ(20℃)
Impedance value within the range is good.
Impedance value “∞” indicates broken wire inside the coil.
Remove the spark plug cap and measure impedance value between primary side lead-wire of
ignition coil cap and negative terminal.
Standard value:3-5.5KΩ±10%(20℃)
2.6 Trigger
** Attention
Trigger inspection can be performed on the engine.
Inspection
Remove protecting plate of vehicle block.
Remove lead-wire connector of trigger.
Measure impedance between blue/white terminal
of lead wire on the engine side and ground wire of
vehicle block.
Standard value:100-200Ω(20℃)
If measured impedance value is beyond the range,
please replace the magneto.