8. Quick charging is forbidden except in emergency.
9. During quick charging, the battery must be removed from the motorcycle first and then be
charged.
10. While battery is exchanged, please do not use liquid-feeding battery.
11. A voltmeter shall be employed to check the state of charged battery.
Service Data
12V-9AH/ dry-charged type
12.3V(stop working for one hour)
Standard:10-15hours; Quick:30minutes
Coiling impedance value(20℃)
Tightening torque Tools
Rectifier bolt 5.0 N·m Universal non-adjustable
spanner
High-voltage coil pinch bolt 9.0 N·m Flywheel remover
Flywheel locknut 5.0 N·m Testing device
Vehicle block protecting plate bolt 9.0 N·m Multimeter
1.2 Fault Diagnosis
No power Unstable power
Battery over discharged Wiring of battery is poorly contacted.
Wiring of battery is not connected. Discharging system is of poor contact.
Fuse fails. Lighting system is of poor contact or short circuit.
Power switch is poorly contacted.
Low voltage Poor charging system
Battery is poorly charged. Wire connector is of poor contact, short circuit or
short line.
Poor contact. Defective voltage and current regulator
Poor charging system. Magneto does not work well.
Poor voltage and current regulator